Field-Test Checklist — Valve Robustness Refactor

Valve robustness refactor cluster (incl. volume_preset fix). Date prepared: 2026-05-23.

This checklist is for a human operator on a real installation. Each step is a discrete observable behaviour: tick the box, record the outcome and (when something goes wrong) attach the diagnostic bundle described at the bottom of the page.

What changed (operator-facing summary)

Change What you will notice
Per-valve finite-state machine (FSM) Internal — no UI change
ValveOperator wraps every switch call Open/close failures now produce a persistent notification in HA, deduplicated per valve and per kind
Unified notifier (ValveNotifier) Notification IDs follow never_dry_<zone>_<kind> — easy to find / filter
volume_preset bug fix Smart valves that previously did not open when you pressed irrigate now open and dispense the configured volume
Manual valve listener (race) No more spurious "manual irrigation detected" right after a controller-driven cycle
Emergency stop Closes every valve in parallel (was sequential) — faster when you have multiple valves
Partial irrigation last_irrigated fix The UI now updates the last irrigated timestamp even when delivery was partial (e.g. timeout reached before target volume)
Leak recovery + escalation On CLOSE_LEAK the operator now re-issues a direct switch.turn_off and re-checks the flow. If the leak persists it calls never_dry.stop (closing every other valve) and raises a CRITICAL persistent notification telling you to shut off the mains water valve.
Real-time deficit update (flow-metered modes) While flow_meter/flow_rate deliveries are running, the zone's deficit_mm now drops live every 2 s (poll interval). On a crash mid-cycle the partial progress is preserved (before this change a crash lost every mm we had already delivered). The end-of-cycle settle is snapshot-based and idempotent with the intermediate writes (no double-counting).

Quick sanity check — automated smoke tests

Before running the manual steps below, run the automated smoke tests against the live installation to verify the integration loads and the core services respond correctly:

cd sw_artifacts
python tests/e2e/smoke.py --no-valves

All 7 tests must pass. If any fail, fix the issue before proceeding. See sw_artifacts/docs/developer_manual.md §7.1 for full setup instructions.


Setup before the test

  • HACS-install NeverDry from the branch that contains the new valve_operator.py, valve_fsm.py, valve_notifier.py files.
  • Restart Home Assistant.
  • Confirm the integration is loaded: Settings → Devices & Services → NeverDry → "1 service" badge is visible.
  • Confirm every zone you intend to irrigate has its delivery mode set (estimated_flow / flow_meter / volume_preset).
  • For volume_preset zones: confirm the volume entity (number.<valve>_volume or equivalent) is reachable from Developer Tools → States.
  • Open Developer Tools → Logbook in another tab — easier to follow what's happening live.

Test A — estimated_flow zone (the simple path)

Pre-conditions: one zone configured with delivery_mode = estimated_flow and a deficit > threshold (or force it via a dummy mark_irrigated then a long enough wait, or set the deficit manually in the developer panel).

  • A.1 — Call never_dry.irrigate_zone with the zone name.
  • A.2 — Within 1–2 s the valve switch turns on in HA.
  • A.3 — At the end of the calculated duration the valve turns off automatically.
  • A.4 — Zone sensor deficit_mm drops to 0 (or close to it).
  • A.5last_irrigated attribute updates to the time of the run.
  • A.6No persistent notifications were created.

If any step fails: stop, grab the log bundle (see bottom), open a GitHub issue with the bundle attached and the step number in the title.

Test B — flow_meter zone with a real flow sensor

Pre-conditions: one zone with delivery_mode = flow_meter and a working flow sensor entity (cumulative L or L/min — both are fine).

  • B.1 — Trigger irrigation.
  • B.2 — Valve opens, flow sensor begins to climb.
  • B.3 — When the delivered volume reaches the target the valve closes by itself.
  • B.4last_volume_delivered ≈ target volume (within a few percent).
  • B.5last_irrigated updated.

Edge case to provoke: physically close the upstream water tap just before triggering. Expected behaviour:

  • B.6 — The valve opens (switch state goes on)…
  • B.7 — …but the flow stays at 0 → after the flow-verify timeout (10 s default) the operator switches the valve off and records ACTUATION_FAILED.
  • B.8 — A persistent notification appears: title ≈ "[WARNING] Valve command failed"; message names the zone and error_detail=actuation_failed.
  • B.9 — Re-open the water tap. The next irrigation succeeds and the notification clears the next time the operator emits a non-failure update for that zone.

Test C — volume_preset zone (the bug fix)

This is the headline of the cluster. Pre-conditions: a Sonoff SWV (or similar) configured with delivery_mode = volume_preset and the corresponding volume_entity (the number.* exposed by ZHA).

  • C.1 — Trigger irrigation. Within the first 3 s: - the volume number entity should update to the calculated target; - the valve switch may either turn on by itself (firmware with dose-and-go) or remain off until the grace window expires.
  • C.2 — After ≤ 3 s the valve is open (state = on). If you had to wait for the grace window, look in the log for "smart valve did not auto-open within 3.0s, sending switch.turn_on".
  • C.3 — Water flows for the duration needed to deliver the configured volume.
  • C.4 — Valve closes itself (state = off).
  • C.5last_irrigated and last_volume_delivered update.

Failure-mode probe: temporarily disable the valve in ZHA (mark it unavailable). Then trigger:

  • C.6 — A "[CRITICAL] Zone disabled" persistent notification appears after the third consecutive failure, or "Valve command failed" appears before that.

Test D — Emergency stop with multiple zones

Pre-conditions: at least two zones with valves, both with a positive deficit.

  • D.1 — Call never_dry.irrigate_all (or trigger from the button entity).
  • D.2 — While the first zone is being irrigated, call never_dry.stop.
  • D.3 — Both valves transition to off within 2 s — note that they should close roughly simultaneously, not one after the other (parallel emergency-stop).
  • D.4is_running returns to False (visible in the integration's diagnostic entities or via developer tools).
  • D.5 — No partial delivery is registered for the zones that hadn't started.

Test E — Manual valve operation (no race)

Pre-conditions: a valve with a flow meter, no irrigation currently running.

  • E.1 — Open the valve manually from HA (e.g. from the switch domain).
  • E.2 — Let it run for ~30 s, then close it manually.
  • E.3 — Within seconds you should see an EVENT_IRRIGATION_COMPLETE in the event bus and the zone's deficit_mm should drop by the measured volume.
  • E.4last_irrigation_source = "manual".

Race check: now trigger an automatic irrigation. While it's running:

  • E.5 — In the last 2 seconds of the cycle (when the controller has set _running=False but the valve is still finishing the close), no manual-irrigation event is fired spuriously. (Before the fix this could falsely log a manual irrigation.) Confirm in Logbook that the only EVENT_IRRIGATION_COMPLETE for that zone has source = "automatic".

Test F — Partial irrigation last_irrigated fix

Pre-conditions: a zone with delivery_mode = flow_meter and a flow sensor that delivers more slowly than the configured delivery timeout would allow for the full target. Easiest reproduction: set a very short delivery_timeout (e.g. 15 s) for the zone, then trigger.

  • F.1 — Trigger irrigation.
  • F.2 — The cycle times out before reaching the full volume → a partial delivery is recorded in the log.
  • F.3The zone's last_irrigated attribute updates to the time of the partial delivery (this was the regression).
  • F.4last_volume_delivered matches what the flow meter reported.

Test H — CLOSE_LEAK recovery and escalation (critical path)

This is the most important test in the cluster. It exercises the "valve stuck open" failure mode, which is the one that can flood the garden if the integration does not react correctly.

H.1 — Recovery succeeds (simulated transient leak)

Pre-conditions: a zone with a flow meter. The flow meter must be readable through HA (Developer Tools → States gives a number).

Setup: arrange a controllable "physical leak" you can clear quickly. Easiest approximation if you cannot induce a real leak: manually pre-set the flow sensor's value via a homeassistant.set_state call right before the operator polls.

  • H.1.a — Run a normal irrigation cycle until close. While the close cycle is verifying flow→0, force the flow sensor to report a non-zero value for ~10 s (set state via developer tools, or open a parallel water tap on the same flow meter).
  • H.1.b — In the HA log you should see: "Valve '<zone>' CLOSE_LEAK detected — attempting recovery (direct switch.turn_off + recheck)".
  • H.1.c — Within ~10 s clear the simulated leak (close the parallel tap, or restore the flow sensor to 0).
  • H.1.d — Log shows: "Valve '<zone>' leak recovery succeeded (flow=0.000)".
  • H.1.e — The irrigation cycle finishes with the zone reset and last_irrigated updated.
  • H.1.fNo persistent notification was created (the recovery handled the leak silently).

H.2 — Recovery fails → emergency stop + CRITICAL notification

Pre-conditions: same flow-meter zone. This test exercises the escalation path, so keep at least one other zone with a valve so you can verify that never_dry.stop propagates.

  • H.2.a — Trigger irrigation. While close-verification is in progress, force the flow sensor to a non-zero value and keep it there for >25 s (10 s leak timeout + 10 s recovery window + buffer).
  • H.2.b — Log shows the recovery attempt (as in H.1.b).
  • H.2.c — Log shows: "Valve '<zone>' leak recovery failed (flow=…)" followed by "stuck-open confirmed after recovery; calling never_dry.stop".
  • H.2.dEvery other valve switch goes off within ~2 s (the operator called never_dry.stop).
  • H.2.e — A persistent notification appears under Settings → System → Notifications. Title contains "[CRITICAL] Valve stuck open". Body explicitly tells you to shut off the main water valve.
  • H.2.f — Clear the simulated leak. Manually dismiss the notification. Run another irrigation on the same zone: it should work normally — recovery state is per-call, not sticky.

H.3 — Recovery is attempted only once per close()

  • H.3.a — Repeat H.2 (force a persistent leak).
  • H.3.b — In the HA log, search for the "attempting recovery" line for that specific zone+timestamp. Confirm there is exactly one occurrence per close() call (not two, not three).

If recovery is attempted more than once per call, file a regression issue with the log bundle (see Diagnostic bundle below) — that would indicate a flag-reset bug in the operator.

Test I — Real-time deficit drop during a flow-metered cycle

Pre-conditions: a zone with delivery_mode = flow_meter and a working flow sensor. Take note of the zone's deficit_mm and last_volume_delivered on the entity card before triggering.

  • I.1 — Trigger irrigation on this zone.
  • I.2 — Open the entity card or the zone-deficit sensor in HA and watch the value. Every 2 s (poll interval) the deficit_mm should drop by flow_delta * efficiency / area. You should see it move multiple times during the cycle, not only at the end.
  • I.3 — When the cycle completes, the final value matches deficit_at_start - delivered_total * efficiency / area (or 0 if the full target was delivered).
  • I.4Crash test (optional but valuable). While the cycle is running, restart HA from Settings → System → Restart. After restart, the zone's deficit_mm should reflect the last real-time value written before the restart — not the original pre-irrigation value. Some mm of irrigation is preserved even on an unclean shutdown.

If you do not see incremental drops, double-check:

  • The delivery mode is flow_meter or flow_rate (estimated_flow has no metering and the deficit only updates at end).
  • The flow sensor entity is reading a numeric value (Developer Tools → States).

Test G — Notifications deduplication

Pre-conditions: force a transient failure on a flow_meter zone (unplug the flow meter; trigger irrigation; plug it back in).

  • G.1 — The first failure produces a persistent notification.
  • G.2 — Repeating the same trigger with the flow meter still unplugged does not stack a second identical notification — the same notification_id is reused (visible in Settings → System → Notifications, only one entry per <zone, kind>).
  • G.3 — Once the meter is back and a successful cycle completes, the persistent notification should be dismissable and not reappear.

Test J — Logging, reload robustness, and controller lifecycle (session 2026-06-19)

J.1 — Version visible in activity log on startup

  • J.1.a — After any HA restart or integration reload, open /config/never_dry_activity.log. The first NeverDry line must read: NeverDry <version> — activity log -> /config/never_dry_activity.log (5 MB x 3) (e.g. NeverDry 0.9.1 — …). If the version is missing, the manifest.json read in _setup_file_logger failed.

J.2 — INFO messages survive integration reload

Background: HA sets the custom_components.never_dry logger level to WARNING after a reload, filtering INFO messages unless we explicitly call setLevel(DEBUG) in _setup_file_logger.

  • J.2.a — While the integration is running, trigger a reload (Settings → NeverDry → ⋮ → Reload).
  • J.2.b — Immediately after, the activity log must show the startup banner (J.1.a) and the Mode B (scheduled): zone=… INFO lines. If only WARNING/ERROR appear, the setLevel fix is missing.

J.3 — External valve close aborts estimated_flow session immediately

  • J.3.a — Start irrigation on an estimated_flow zone with enough deficit for a session lasting several minutes.
  • J.3.b — While the valve is open, close it directly from the Zigbee/ZHA interface (not from the NeverDry UI).
  • J.3.c — Within 1–2 s the activity log must show: Valve '<entity>' closed externally after Xs — aborting estimated_flow wait
  • J.3.d — Within the same second: SESSION_RESULT zone=… volume_delivered_L=<proportional> deficit_mm_post=<reduced> The deficit must reflect only the water actually delivered (not the full planned amount).
  • J.3.e — The CLOSE_VERIFICATION_FAILED ERROR that follows is expected (controller tries to close an already-closed valve) and is not a regression.

J.4 — Graceful stop when config changes during irrigation

  • J.4.a — Start irrigation on an estimated_flow zone (session long enough to give you 30+ s to act).
  • J.4.b — While the valve is open, edit any zone parameter (e.g. area m²) via Settings → NeverDry → Configure.
  • J.4.c — The activity log must show, within ~1 s of saving: DEBUG Config updated via edit_zone — zone edited: <zone> INFO Config entry data changed — reloading integration INFO Irrigation stopped by user after 0 zones ← graceful stop INFO SESSION_RESULT zone=… volume_delivered_L=<partial> INFO NeverDry <version> — activity log → … ← new controller
  • J.4.d — The valve is closed after the reload (not left open). Verify in HA entity state.
  • J.4.e — The deficit is updated proportionally to the water delivered before the stop — not zeroed by the new controller's manual-detection logic.

J.5 — No spurious "manual irrigation detected" after NeverDry-initiated close

Background: before the _controller_closing fix, the close event fired by operator.close() was processed by _on_valve_state_change after the operator reached IDLE, triggering a false manual-irrigation reset.

  • J.5.a — Start and complete a short estimated_flow irrigation (let it run to natural completion, do not close manually).
  • J.5.b — In the activity log, confirm there is no Manual irrigation detected line in the 2 s following the Valve '<entity>' close latency … line.
  • J.5.cdeficit_mm after the cycle matches deficit_pre - delivered_mm * efficiency (not 0).

J.6 — Config change suppressed when data is unchanged

  • J.6.a — Open Settings → NeverDry → Configure → edit a zone → change nothing → save.
  • J.6.b — The activity log must not show Config entry data changed — reloading integration. No reload must occur. The integration keeps running without interruption.

Diagnostic bundle — how to capture and download the HA add-on log

Use this whenever a step above fails or you see a notification you don't understand. The bundle goes onto a GitHub issue or, for personal debugging, into the project's ~/.code_reader/ inbox.

One-time setup

  • Settings → System → Logs → set log level for the integration: paste this into Developer Tools → Services and call once: yaml service: logger.set_level data: custom_components.never_dry: debug This stays in effect until HA restarts.

After the failed step

  1. Reproduce the failure with the debug log level active.
  2. Download the full Home Assistant log:
    • Settings → System → Logs → "Load full Home Assistant log" (top of page) → Download button (top right). Saves a home-assistant.log file.
  3. If running Home Assistant OS / Supervised, also download the Core add-on log:
    • Settings → Add-ons → Home Assistant Core → "Log" tab → arrow icon (top right of the log pane) → "Download log".
  4. Capture the integration diagnostics:
    • Settings → Devices & Services → NeverDry → ⋮ menu → "Download diagnostics". Saves a JSON file with the integration config (secrets are scrubbed automatically).
  5. Capture a screenshot of the persistent notifications panel if any notification is part of the failure.
  6. Note, in the same order:
    • The HA version and NeverDry version.
    • Which test step failed (e.g. Test C, step C.6).
    • The time of the failure (UTC + local), so we can grep the log.
  7. Bundle all of the above (home-assistant.log, add-on log, diagnostics JSON, screenshot, notes) into a single .zip:
    • File name pattern: neverdry_test_YYYYMMDD_HHMM_step.zip.
  8. Attach the zip to a GitHub issue (never-dry/NeverDry/issues/new) with a title like "Field test — step C.6 failure".

CLI shortcut for power users

If you have SSH access to the HAOS host (Advanced SSH & Web Terminal add-on):

# Full log of the Home Assistant Core service
ha core logs --no-color > home-assistant.log

# Last 1000 lines only (often enough for a recent failure)
ha core logs --lines 1000 --no-color > recent.log

# Search for our integration during a given hour
grep -i "never_dry\|valve" home-assistant.log | grep "14:3[0-9]:"

The ha CLI also exposes:

ha supervisor logs    # supervisor-level events (zigbee restarts etc.)
ha host logs          # OS-level (HAOS only)

After-test wrap-up

Once every test box above is ticked:

  • Mark the cluster items closed on the project tracker.
  • Update the README and info.md if any user-visible behaviour changed (the volume_preset fix and the notifier strings will probably justify a short release note).
  • Open the next cluster (absolute watchdog, restart recovery, zone health counter) — they all build on the FSM/operator and on the leak-recovery path now in production.

If any test failed and the issue is structural, do not roll back the whole cluster — the most likely fault is in the operator's state-resolution or in one specific delivery mode. The FSM unit tests already cover the pure logic; ship a targeted fix.


Revision history

Date Change
2026-05 Initial — manual field-test checklist.