This document describes the hardening applied to the NeverDry integration controller layer — the code above the per-valve FSM/operator — and identifies remaining gaps. It complements valve-state-machine.md, which covers the per-valve FSM and ValveOperator.


What is hardened

1. Logger level persistence through HA reloads

Problem. When HA reloads a config entry, it resets the custom_components.never_dry logger level to WARNING, silently dropping all INFO and DEBUG lines. The never_dry_activity.log file appeared to stop updating after any reload.

Fix. _setup_file_logger calls nd_logger.setLevel(logging.DEBUG) explicitly after attaching the RotatingFileHandler. _teardown_file_logger restores setLevel(logging.NOTSET) so the level is not leaked across unloads. The startup line now includes the integration version (NeverDry 0.9.1 — activity log → ...) to make restarts visible in the log.

Note. A reload re-executes async_setup_entry but does not invalidate the Python module cache (sys.modules). Changes to .py files are only picked up after a hard HA restart.


2. Controller lifecycle — no duplicate instances

Problem. On config entry reload, async_setup_entry created a new IrrigationController while the previous one was still alive. Both registered the same HA services and the same valve-state listeners. Result: double watchdog timers, double SESSION_RESULT lines, and unpredictable irrigation behaviour.

Fix. Two-part:

  1. sensor.py stores the controller reference in hass.data[DOMAIN][f"_controller_{entry.entry_id}"] immediately after creation.
  2. async_unload_entry pops the reference and calls controller.async_stop() before async_unload_platforms. This guarantees the old controller is fully terminated before the new one is created.

async_stop() design. Sets _stop_requested = True, then does with contextlib.suppress(Exception): await task. It does not call task.cancel(). Cancellation raises CancelledError, which bypasses except Exception in the irrigation loop's finally block — leaving the valve open and losing the SESSION_RESULT. The graceful path lets the loop exit its _wait_with_stop_check poll within ~1 second, write the session result, and close the valve cleanly before the new controller starts.


3. External valve close detection in estimated_flow mode

Problem. If the user closed the valve manually during an estimated_flow delivery, the controller kept waiting for the full estimated duration. Elapsed volume and deficit adjustment were wrong (over-counted).

Fix. _wait_with_stop_check(duration_s, valve_entity=None) polls hass.states.get(valve_entity).state == "off" once per second alongside the _stop_requested check. Returns the elapsed seconds so the upstream caller can compute the correct partial volume. Analogous behaviour already existed for flow_meter mode.


4. Spurious "Manual irrigation detected" after NeverDry close

Problem. Race condition between the ValveOperator FSM and the HA state change event bus. When NeverDry closes a valve, operator.close() transitions the FSM to IDLE synchronously. The HA entity state change event (valve → off) is dispatched later, on the next event loop iteration. _on_valve_state_change saw the off event without knowing that NeverDry had just closed the valve, and classified it as a manual close.

Fix. self._controller_closing: set[str] tracks valve entity IDs currently being closed by NeverDry. _close_valve adds the entity before calling operator.close() and removes it in finally. In _on_valve_state_change, if entity_id in self._controller_closing the close event is silently skipped (NeverDry-initiated, not manual). est_duration was also added to the irrigation start log line.


5. Config flow guard against spurious reloads

Problem. All four async_update_entry call sites in config_flow.py (model_params, edit_zone, add_zone, remove_zone) called async_update_entry unconditionally — even when the user saved without changing any field. Every save triggered a reload, which during active irrigation caused the controller to stop, the valve to close, and the deficit to reset incorrectly.

Fix. Each call site is now guarded with:

if new_data != dict(self._config_entry.data):
    _LOGGER.debug("Config updated via <step> — changed keys: %s", changed)
    self.hass.config_entries.async_update_entry(...)

No data change → no update → no reload → irrigation continues uninterrupted. The debug log records exactly which keys changed, making future spurious-reload diagnoses straightforward.


6. CLOSE_LEAK: no spurious CRITICAL on successful recovery

Covered in valve-state-machine.md §CLOSE_LEAK recovery and escalation. Summary: _notify_failure(CLOSE_LEAK) is now silent; CRITICAL only fires via _escalate_stuck_open() when recovery fails.

7. Per-zone stop + external close in flow modes

Problem. Two coupled gaps surfaced on the Giardino Ortensia zone (flow_meter / flow-rate mode). (a) When its Sonoff valve auto-closed in hardware (~600 s) the flow-rate delivery loop did not detect it: it kept polling a dead flow sensor for the full delivery_timeout (up to 3600 s), pinning the zone is_irrigating for an hour. The external-close detection existed only for estimated_flow (_wait_with_stop_check), not for the two flow-metered loops. (b) The "Reset valve" button only clears the FSM MAINTENANCE lock — it does not stop a running delivery loop — so the only escape was the global never_dry.stop, which the Lovelace card did not expose. The card could start a session but not stop one.

Fix.

  • External-close early-exit in _deliver_flow_meter and _deliver_flow_rate: a new _valve_closed_externally(zone) helper checks whether the valve switch reads off each poll; on a confirmed off the loop finalises the partial delivery and exits instead of waiting out the timeout. estimated_flow and volume_preset already did this; the FSM change in valve-state-machine.md §External / hardware auto-close is required so the subsequent _close_valve does not raise a spurious CLOSE_VERIFICATION_FAILED.
  • Per-zone stop: new service never_dry.stop_zone + _handle_stop_zone, driven by a _stop_zone flag that the delivery loops honour via _should_abort(zone) (alongside the global _stop_requested). It closes the single zone's valve, cancels any manual safety watchdog and clears is_irrigating, leaving other zones untouched. Exposed as a per-zone StopButton and a Stop action in the NeverDry Zone Card.

Layered reliability picture (as of 2026-06-27)

Delivery layer (controller.py)
  ├── volume/time target met → _close_valve
  ├── external close detected — estimated_flow (_wait_with_stop_check)
  ├── external close detected — flow_meter / flow_rate loops
  ├── per-zone stop (stop_zone + _stop_zone via _should_abort)
  └── _stop_requested flag exits poll loop within ~1s

Valve layer (valve_operator.py)
  ├── switch confirmation (L2): OPEN_FAILED / CLOSE_VERIFICATION_FAILED
  ├── flow confirmation (L3): ACTUATION_FAILED / CLOSE_LEAK
  ├── CLOSE_LEAK recovery: direct retry + recheck
  ├── Escalation only when recovery fails (CRITICAL)
  └── Software watchdog (absolute max_open_duration)

Hardware layer (Sonoff SWV / Zigbee)
  └── HW max_duration interlock (entity or MQTT direct)

Integration lifecycle (controller + __init__.py)
  ├── Graceful stop on unload (await, not cancel)
  ├── No duplicate controller instances across reloads
  ├── No spurious reloads on unchanged config save
  ├── No spurious manual-close events (_controller_closing)
  └── Logger level persists through reloads

Remaining gaps

HA crash resilience — risk is mode-dependent

This is the most important gap to understand, because the risk is not uniform across zones — it depends on the delivery mode configured.

Delivery mode HA crash behaviour Risk
volume_preset The valve receives the target volume via number.set_value and stores it in hardware firmware. It self-closes when the volume is reached — independently of HA. A crash after set_value has been sent does not leave the valve open. LOW
estimated_flow The valve is a dumb on/off relay. NeverDry sends turn_on and waits a calculated duration before sending turn_off. If HA crashes between the two, the valve stays open indefinitely. HIGH
flow_meter Same as estimated_flow — HA must send turn_off. The flow sensor only controls when NeverDry decides to close; it cannot close the valve by itself. HIGH

Consequence for this gap (HA restart recovery). The implementation priority depends on which delivery modes are actually in use. If all zones use volume_preset, the HA crash risk is already mitigated at the hardware level and this fix is a nice-to-have. If any zone uses estimated_flow or flow_meter, this fix is HIGH priority.

Layer 3 partial mitigation. The hardware interlock sets a max_duration timer on the valve via number entity or MQTT. If configured, this closes estimated_flow/flow_meter valves even if HA crashes — acting as a hardware fuse. However, hw_max_duration_topic is not yet exposed in the config flow, so it is not available to end users.

Recommendation. For Sonoff SWV (and any valve that accepts a volume target in its firmware), volume_preset mode is the correct choice if HA crash resilience is a priority. It trades actuation verification (L3) and CLOSE_LEAK detection for hardware-level close guarantee.

Gap Risk
HA restart recovery (estimated_flow/flow_meter zones) — valve stays open if HA crashes mid-irrigation. HIGH for those modes
HW interlock not in config flowhw_max_duration_topic/payload only configurable via YAML, invisible to UI users. MEDIUM
volume_preset FSM bypass — no actuation verification (L3), no CLOSE_LEAK detection for smart valves. Acceptable trade-off for volume-target valves; document it per valve type. LOW (mitigated by hardware metering)
Flow meter hardware fault (Ortensia) — flow sensor always reads 0. flow_meter mode non-functional on that zone. LOW (zone reconfigured to estimated_flow)
CLOSE_VERIFICATION_FAILED recurring (Melino) — hardware Zigbee issue; valve closes physically but confirmation never arrives. LOW (valve is closed; notification is spurious)
Config flow: missing field validation — inconsistent zone config (e.g. flow_meter mode with no flow sensor) not caught at setup time. MEDIUM
Flow meter guard — no fallback if flow sensor drops to unavailable mid-session. MEDIUM
Latency tracker cold start — first MIN_SAMPLES=3 cycles use fixed timeouts; slow Zigbee valves may time out incorrectly at first. LOW
Test J.5 / J.6 unverified in field_controller_closing and CRITICAL suppression need HA restart before field verification.

Design invariants to preserve

  1. async_stop() must use await task (not task.cancel()). Cancel bypasses the finally block and leaves the valve open.
  2. _notify_failure(CLOSE_LEAK) must remain silent. CRITICAL for CLOSE_LEAK is only sent by _escalate_stuck_open().
  3. _controller_closing must be populated before operator.close() is called and cleared in finally. Do not add await points between add and discard without re-examining the guard logic.
  4. async_update_entry in config_flow.py must always be guarded by if new_data != dict(entry.data).
  5. The controller reference in hass.data[DOMAIN][f"_controller_{entry.entry_id}"] must be populated before any valve is opened. async_unload_entry depends on it to find and stop the controller.