Skip to content

CEA faults #3993

Description

@chuchululily-jpg

Applying fix for Apple Silicon
City Energy Analyst version 3.39.4
Running cea demand with the following parameters:

  • general:scenario = /Users/lily/Desktop/UNI/0155 sustainable citie/project 2/dummy/Barratt London
    (default: {general:project}/{general:scenario-name})
  • general:multiprocessing = True
    (default: True)
  • general:number-of-cpus-to-keep-free = 1
    (default: 1)
  • general:debug = False
    (default: False)
  • demand:buildings = ['B1000', 'B1001', 'B1002', 'B1003', 'B1004', 'B1005', 'B1006', 'B1007']
    (default: [])
  • demand:loads-output = ['PV', 'GRID', 'GRID_a', 'GRID_l', 'GRID_v', 'GRID_ve', 'GRID_data', 'GRID_pro', 'GRID_aux', 'GRID_ww', 'GRID_hs', 'GRID_cs', 'GRID_cdata', 'GRID_cre', 'E_sys', 'Eal', 'Ea', 'El', 'Ev', 'Eve', 'Edata', 'Epro', 'Eaux', 'E_ww', 'E_hs', 'E_cs', 'E_cre', 'E_cdata', 'Qhs_sen_shu', 'Qhs_sen_ahu', 'Qhs_lat_ahu', 'Qhs_sen_aru', 'Qhs_lat_aru', 'Qhs_sen_sys', 'Qhs_lat_sys', 'Qhs_em_ls', 'Qhs_dis_ls', 'Qhs_sys_shu', 'Qhs_sys_ahu', 'Qhs_sys_aru', 'Qcs_sys_scu', 'Qcs_sys_ahu', 'Qcs_sys_aru', 'DH_hs', 'Qhs_sys', 'Qhs', 'DH_ww', 'Qww_sys', 'Qww', 'DC_cs', 'Qcs_sys', 'Qcs', 'DC_cre', 'Qcre_sys', 'Qcre', 'DC_cdata', 'Qcdata_sys', 'Qcdata', 'NG_hs', 'COAL_hs', 'OIL_hs', 'WOOD_hs', 'SOLAR_hs', 'NG_ww', 'COAL_ww', 'OIL_ww', 'WOOD_ww', 'SOLAR_ww', 'Qcs_sen_scu', 'Qcs_sen_ahu', 'Qcs_lat_ahu', 'Qcs_sen_aru', 'Qcs_lat_aru', 'Qcs_sen_sys', 'Qcs_lat_sys', 'Qcs_em_ls', 'Qcs_dis_ls', 'Qhpro_sys', 'Qcpro_sys', 'QH_sys', 'QC_sys']
    (default: [])
  • demand:massflows-output = ['mcpww_sys', 'mcptw', 'mcpcs_sys', 'mcphs_sys', 'mcpcs_sys_ahu', 'mcpcs_sys_aru', 'mcpcs_sys_scu', 'mcphs_sys_ahu', 'mcphs_sys_aru', 'mcphs_sys_shu', 'mcpcre_sys', 'mcpcdata_sys']
    (default: [])
  • demand:temperatures-output = ['T_int', 'T_ext', 'theta_o', 'Tww_sys_sup', 'Tww_sys_re', 'Tcre_sys_re', 'Tcre_sys_sup', 'Tcdata_sys_re', 'Tcdata_sys_sup', 'Ths_sys_sup_aru', 'Ths_sys_sup_ahu', 'Ths_sys_sup_shu', 'Ths_sys_re_aru', 'Ths_sys_re_ahu', 'Ths_sys_re_shu', 'Tcs_sys_sup_aru', 'Tcs_sys_sup_ahu', 'Tcs_sys_sup_scu', 'Tcs_sys_re_aru', 'Tcs_sys_re_ahu', 'Tcs_sys_re_scu', 'Ths_sys_sup', 'Ths_sys_re', 'Tcs_sys_sup', 'Tcs_sys_re']
    (default: [])
  • demand:resolution-output = hourly
    (default: hourly)
  • demand:use-dynamic-infiltration-calculation = False
    (default: False)
  • demand:overheating-warning = True
    (default: True)
    Running demand calculation for scenario /Users/lily/Desktop/UNI/0155 sustainable citie/project 2/dummy/Barratt London
    Running demand calculation with dynamic infiltration=False
    Running demand calculation with multiprocessing=True
    Running demand calculation for the following buildings=['B1000', 'B1001', 'B1002', 'B1003', 'B1004', 'B1005', 'B1006', 'B1007']
    read input files
    Traceback (most recent call last):
    File "/Users/lily/Documents/CityEnergyAnalyst/envs/cea/lib/python3.8/site-packages/cea/worker.py", line 146, in worker
    run_job(config, job, server)
    File "/Users/lily/Documents/CityEnergyAnalyst/envs/cea/lib/python3.8/site-packages/cea/worker.py", line 108, in run_job
    script(config=config, **parameters)
    File "/Users/lily/Documents/CityEnergyAnalyst/envs/cea/lib/python3.8/site-packages/cea/api.py", line 60, in call
    self._runner.call(*args, **kwargs)
    File "/Users/lily/Documents/CityEnergyAnalyst/envs/cea/lib/python3.8/site-packages/cea/api.py", line 38, in script_runner
    script_module.main(config)
    File "/Users/lily/Documents/CityEnergyAnalyst/envs/cea/lib/python3.8/site-packages/cea/demand/demand_main.py", line 145, in main
    demand_calculation(locator=locator, config=config)
    File "/Users/lily/Documents/CityEnergyAnalyst/envs/cea/lib/python3.8/site-packages/cea/demand/demand_main.py", line 82, in demand_calculation
    building_properties = BuildingProperties(locator, weather_data, building_names)
    File "/Users/lily/Documents/CityEnergyAnalyst/envs/cea/lib/python3.8/site-packages/cea/demand/building_properties.py", line 79, in init
    prop_HVAC_result = get_properties_technical_systems(locator, prop_hvac).set_index('Name')
    File "/Users/lily/Documents/CityEnergyAnalyst/envs/cea/lib/python3.8/site-packages/cea/demand/building_properties.py", line 749, in get_properties_technical_systems
    on='Name').merge(df_emission_dhw[fields_emission_dhw],
    File "/Users/lily/Documents/CityEnergyAnalyst/envs/cea/lib/python3.8/site-packages/pandas/core/frame.py", line 3767, in getitem
    indexer = self.columns._get_indexer_strict(key, "columns")[1]
    File "/Users/lily/Documents/CityEnergyAnalyst/envs/cea/lib/python3.8/site-packages/pandas/core/indexes/base.py", line 5877, in _get_indexer_strict
    self._raise_if_missing(keyarr, indexer, axis_name)
    File "/Users/lily/Documents/CityEnergyAnalyst/envs/cea/lib/python3.8/site-packages/pandas/core/indexes/base.py", line 5941, in _raise_if_missing
    raise KeyError(f"{not_found} not in index")
    KeyError: "['class_dhw'] not in index"

Metadata

Metadata

Assignees

No one assigned

    Labels

    No labels
    No labels

    Type

    No type

    Projects

    No projects

    Milestone

    No milestone

    Relationships

    None yet

    Development

    No branches or pull requests

    Issue actions